ProStream and Hystream, two modified Polyethersulfone (mPES) membrane chemistries, offer superior selectivity for a wide range of applications.

Repligen manufactures  two membrane chemistries: ProStream and HyStream in both ultrafiltration and microfiltration pore sizes. Both are modified Polyethersulfone (mPES) membranes validated for use in cGMP processes. The modification, achieved by the addition of a second polymer into the pre-casting membrane solution, ensures total and consistent surface modification.

Balanced  flux and selectivity are achieved using a controlled manufacturing process that enables tight control of the membrane pore size. The manufacturing process ensures a controlled transition from the selective surface to the microporous support.
 
  • No breakthrough of the ultrafiltration skin, which maximizes selectivity performance
  • Enhanced microporous substructure pore size and even transition, which maximize flux
  • Reduced number of manufacturing steps, which reduces cost and promotes excellent consistency and reliability

Both ProStream and HyStream membranes are available in TangenX™ SIUS™ Single-use Cassettes and TangenX™ PRO  Reusable Cassettes. Standard disc formats and custom configurations may be die cut from sheet stock upon request.

Membrane selection guide

  • In general, select a Molecular Weight Cut-off (MWCO) that is 3 to 6 times smaller than the protein or other molecule you want to retain.

  • If obtaining highest possible flow rates is most critical, select a more open MWCO membrane at the lower end of the range (3x).

  • If retention is the main objective, select a tighter MWCO membrane at the upper end of the range (6x).

There are other factors can influence the selectivity and retentivity of a membrane. The shape of a molecule, presence of other solutes, pressure, adsorption and ionic conditions may affect membrane performance. A Repligen Field Application Specialist can help guide membrane selection for specific applications.

ProStream is neutrally charged, which minimizes non-specific protein binding. Unmodified PES has an inherent negative charge and will have non-specific binding.

ProStream membrane is neutrally charged, rendering it low binding for enhanced flux and recovery. The membrane has excellent chemical resistance and very low extractables, with performance comparable to Millipore Biomax, Pall Omega.

  • Neutrally balanced charge / Low protein binding
  • Ideal for downstream ultrafiltration processes where high product recovery is important
  • Modified to minimize protein absorption due to non-specific binding
  • Process flux and product yield higher than with unmodified PES membranes

Available in multiple pore sizes with the following defined 
Molecular Weight Cut-Offs (MWCO)

0.65kD, 1kD, 3kD, 5kD, 10kD, 30kD, 50kD, 100kD, 300kD

Because HyStream membrane is modified to be very hydrophilic,  the contact angle is lower than neutrally charged membranes.

HyStream membrane is extremely hydrophilic in nature, resisting fouling from hydrophobic species such as fat, lipids, and various antifoam agents.  The membrane has good chemical resistance and offers an alternative to RC membranes in some cases, with performance comparable to Millipore Ultracel, and Sartorius Hydrosart.

  • Hydrophilic - Minimal fouling by hydrophobic molecules / Low protein binding
  • Ideal for upstream and downstream filtration operations where minimal fouling and high flux rates are important
  • Prevents the dramatic decrease in flow rate that typically occurs when hydrophobic species are present

Available in multiple pore sizes with the following defined
Molecular Weight Cut-Offs (MWCO):


Ultrafiltration: 5kD, 10kD, 30kD, 50kD, 100kD, 300kD
Microfiltration: 0.1um , 0.2µm, 0.45µm, and 0.65µm

Uniform pore distribution

The selective portion of an ultrafiltration membrane is the shiny surface layer known as the “skin” of the membrane. The layer beneath the skin is made up of a “finger pore” structure that supports the skin and facilitates liquid flow.

The scanning electron micrograph image shows uniformity in the finger pores of the TangenX™ membrane substructure.  This allows for minimal particle entrapment, which results in low fouling and maximum fluid flow. Repligen has developed this membrane substructure to ensure a defect-free surface and to provide maximum adhesion to the substrate while achieving highest possible flow rates.

Porous substructure of the TangenX™ ProStream 10K membrane

High selectivity

Ultrafiltration membranes utilize nominal Molecular Weight Cut-offs as a measure of the pore size distribution across the membrane surface. The more uniform the pore size, the better the membrane’s selectivity is. A narrow pore size distribution means the membrane has high selectivity; i.e.,  the membrane has a high ability to differentiate between macromolecules of a more similar size.

The curves shown graphically represent the selectivity profile of several different membrane Molecular Weight Cut-offs offered by Repligen. Each membrane selectivity curve is distinctly separated from one another with no overlap and shows a high degree of selectivity. This leads to higher process performance and product yield.                 

High flux

The graph shows an optimization of transmembrane pressure (TMP) with a 30mg/ml monoclonal antibody feed stream. Under standardized conditions, Repligen's flux rate is highest at any given TMP. This results in greater process efficiency, a reduction in process time, and cost savings. 

Source: IBC Applications for Biopharmaceuticals, La Jolla, CA, June 1-3 2009.

Designed specifically for critical applications, TangenX membranes are ideal for a broad range of cross-flow applications, from microfiltration (MF) harvest through ultrafiltration (UF) concentration, diafiltration, and fractionation. Exceptional membrane performance benefits all applications by reducing process time and increasing product yield.

 

Applications

Processes

Features

Advantages

Ultrafiltration

Processing of protein solutions containing biomolecules (albumin,  mAbs, lgG, lgM, hormones, growth factors, etc.)

Concentration
Buffer exchange

 

Depyrogenation
Membrane purification

High flux
High selectivity
Void free
Low protein binding
High chemical resistance

Less membrane surface
Smaller system
High yield
Easy, rapid clean-up
Excellent regeneration

Microfiltration

Processing of cell culture(s)
Fermentation broth

Harvest

 

Clarification
Concentration

High flux
High selectivity
Void free
Low protein binding
High chemical resistance
Less membrane
Smaller system
High yield
Easy, rapid clean-up
Excellent regeneration

Membrane discs are available using HyStream or ProStream in all porosities. TangenX™ membrane cut discs are available in common diameters to fit conventional stirred cells and the TangenX™ X-Flo76 membrane screening system. Discs are disposable; however, if appropriate cleaning measures are taken, they may be washed and reused typically 10 to 20 times. Disc sizes are available in 25 to 90 mm. Contact a Repligen representative for special die configuration needs.

Below is the list of membrane disc sizes available.  Please specify membrane type and molecular weight cut-off when ordering.

Membrane Size

Quantity

Part Number

25 mm round

12 pack

D025

44 mm round

12 pack

D044

47 mm round

12 pack

D047

63 mm round

12 pack

D063

76 mm round

12 pack

D076

90 mm round

12 pack

D090

203 mm x 228 mm rectangle

1 pack

SR01

203 mm x 228 mm rectangle

5 pack

SR05

The X-Flo76 Membrane Screening System utilizes 76 mm membrane discs to determine the most advantageous balance of selectivity and flux.

  • Efficient predictable membrane screening
  • Representative tangential flow characteristics
  • Convenient processing of 15-500 mL
  • Quick easy assembly (Area: 30 cm2)

TangenX™ X-Flo76 System

 
 
Scroll To Top