Still using legacy KF Comm software?
See KF Comm 2 in action.
KF Comm2 Software, backward compatible with legacy KrosFlo® KR2i and KrosFlo® KMPi Systems, can be conveniently installed on most computers using the Windows Operating System. The software is compatible with Chrome, Mozilla, Firefox and Microsoft Explorer browsers and is always current with automatic software and firmware updates.
KF Comm 2 software may be validated for GMP processes with optional 21 CFR Part 11 compliance.
Designed for use with KrosFlo® KR2i and KrosFlo® KMPi TFF Systems
Compatible with multiple
web browsers
21 CFR Part 11 option
Login module with
electronic signature for tracking experiments
13 modes of operation
Realtime tracking from setup to analysis
KF Comm 2 software may be validated for GMP processes with optional 21 CFR Part 11 compliance.
KF Comm 2 Software
Microsoft Surface Pro 4
Real-time operating parameters
Processing parameters
Process Control Modes | Primary Application | |
---|---|---|
M |
Manual Mode |
Manual operation of pumps and auxiliary components |
CONT |
Continuous Mode |
Manual operation of pumps and auxiliary components with operator interface step of operation (concentration and diafiltration) |
C |
Concentration Mode |
Simple concentration of the process solution. Automated flushing of the hollow fiber filter |
C/D |
Concentration / Diafiltration |
Concentration and then diafiltration of the process solution in succession |
C/D/C |
Concentration / Diafiltration / Concentration |
Diafiltration of the process solution with one buffer before concentration of the process solution a second time |
C/D/D/C |
Concentration / Diafiltration / Diafiltration / Concentration |
Diafiltration of the process solution with two different buffers in succession before concentration of the process solution a second time |
CFC |
Constant Feed Concentration |
Concentration of the solution while maintaining a constant feed weight |
CF/D/C |
Constant Feed Concentration / Diafiltration / Concentration |
Concentration of the solution while maintaining a constant feed weight, then washing the solution with a buffer during diafiltration, followed by further concentration of the solution |
V |
*NEW* Control mode (Vacuum Mode) |
Use Constant Feed Mode and/or Diafiltration Mode without the need of auxiliary pumps. The solution is drawn into the Feed reservoir by the vacuum created in the reservoir as the solution permeates out of the filter |
F |
*NEW* Flushing Mode |
Flush mode |
NWP |
*NEW* Normalized Water Permeability Mode |
Used to determine filter cleanliness after cleaning and used to determine the water flux of a new module |
C |
*NEW* Cleaning Mode |
Clean mode |
FE |
*NEW* Flux Excursion Mode |
Measure flux rate |