product features

Minimize lentiviral vector degradation

Short residence times (as low as 30 seconds) for high-throughput processes

Gentle elution conditions to preserve lentiviral vector integrity

High yield and purity

Twice the target molecule yield compared to typical ion exchange capture

Effective clearance of cleaved and truncated VSV-G, host cell protein, and host cell DNA

Scalable and reusable

Binding capacity scales linearly with column size

Maintains 80% capacity over 100 simulated sanitization cycles using 0.5 NaOH

Effective lentiviral vector purification

AVIPure HiPer PL specifically targets the phospholipid envelope, making it highly selective for intact lentiviral particles. This unique feature avoids co-purification of free or truncated VSV-G, a common impurity in lentiviral harvests that often associates with host cell proteins (HCPs). By capturing only full, enveloped particles, AVIPure PL improves both purity and yield in a single chromatography step.

Conceptual illustration of lentiviral vectors showing the phospholipid bilayer

Why target the phospholipid envelope?

The phospholipid membrane is a defining characteristic of intact lentiviral vectors, making it an effective target for purification. Unlike traditional approaches that can co-capture free or truncated VSV-G fragments present in the harvest, AVIPure® HiPer™ PL resin binds the phospholipid envelope found on intact particles. This selective capture mechanism helps improve impurity clearance while maintaining high vector recovery and supporting robust lentiviral purification processes.

Key resin features:

  • Selective capture of intact enveloped viruses
  • Mild elution (300 mM NaCl, neutral pH) to maintain virus integrity
  • Robust NaOH tolerance (0.5 M, 100 cycles) for reliable reuse
  • Available in customizable OPUS® pre-packed column formats
  • Short lead times to accelerate your path to clinic

Preserve lentiviral vector stability

Speed and stability are critical for enveloped viruses like lentivirus. AVIPure HiPer Phopsopholipid resin supports short residence times—30 seconds or less with a 5 cm bed height—and mild elution conditions that maintain the structural integrity and infectivity of your vector. These optimized conditions also reduce the need for extensive downstream polishing steps.

Unlike typical anion exchange processes, which require high-salt elution conditions, the AVIPure HiPer PL resin is compatible with multiple gentle elution buffers to preserve lentivirus stability:

  • Buffer 1: 112 mM Arginine-HCl, 150 mM NaCl, 50 mM Hepes pH 7.5
  • Buffer 2: 300 mM NaCl, 50 mM Hepes pH 7.5
  • Buffer 3: 75 mM MgCl₂, 150 mM NaCl, 50 mM Hepes pH 7.5

If further purification is required, AVIPure HiPer PL resin can be seamlessly integrated with custom surface marker-specific capture resins for multi-step workflows.

 AVIPure HiPer PL resin is compatible with multiple gentle elution buffers to preserve lentivirus stability.

AVIPure HiPer PL resin is compatible with multiple gentle elution buffers to preserve lentivirus stability.

Table and bar chart comparing lentiviral transducing unit yield. AVIPure HiPer PL direct capture achieved 54% total TU yield, recovered in the 300 mM NaCl fraction, versus 23% total yield with a QA-functionalized PES membrane.

Achieve 2X target molecule recovery

The AVIPure HiPer PL resin direct capture achieved an overall transducing unit recovery of 54%, more than twice the recovery obtained by the QA-functionalized PES membrane, which recovered 23% of the transducing units.

Request a sample

Unlocking two-fold lentiviral vector recovery with integrated affinity capture

In a case study, resin performance was evaluated as part of an integrated process where tangential flow depth filtration (TFDF) supports the perfusion culture while continuously generating clarified, lentivirus-containing permeate. This permeate was directed to the affinity-capture AVIPure HiPer PL resin without an additional depth-filtration step.

View Webinar

Bar charts comparing lentiviral vector recovery through capture. The conventional depth filtration and AEX route decreased from 100% starting material to 50% after harvest and 11.5% after capture, while the TFDF and AVIPure HiPer PL affinity route retained 100% through harvest and 54% after capture.

Selective purification of lentiviral vector with high purity

By targeting the lentiviral envelope rather than generic surface characteristics, the AVIPure HiPer PL resin enables selective capture of intact lentiviral particles while reducing key process-related impurities. The result is a highly purified product stream that can help simplify downstream processing, support regulatory expectations for impurity clearance, and improve overall process efficiency from development through commercial manufacturing

Line graph showing AVIPure HiPer PL Resin stability over 100 reuse cycles with 0.5 N NaOH cleaning, with relative yield measured by p24 ELISA remaining above 90% through cycle 100.

A simulated cycling study involved a 5-hour hold in 0.5 M NaOH between product cycles. Each hold was equivalent to 20 cycles (5 minutes per cycle). Over 100 simulated cycles were conducted in total. The AVIPure HiPer PL resin maintained > 80% yield over 100 simulated CIP cycles.

Built for manufacturing: scalable, reusable, and reliable

AVIPure HiPer PL resin delivers scalability and robustness, with binding capacity that scales linearly with column size. The resin can withstand up to 100 sanitization cycles with 0.5 M NaOH, while maintaining >80% recovery, supporting cleaning and reuse for optimal process economics.

Pair AVIPure HiPer PL resin with OPUS® pre-packed columns for convenience, consistency, and speed. Columns are customizable to meet your specifications, with short lead times to keep your project on track.

Line graph showing AVIPure HiPer PL Resin stability over 100 reuse cycles with 0.5 N NaOH cleaning, with relative yield measured by p24 ELISA remaining above 90% through cycle 100.

When to use AVIPure HiPer PL Affinity Resin

This resin is best suited for:

  • Lentiviral vector purification for gene therapy manufacturing
  • Capture of other enveloped molecules with phospholipid membranes (e.g., exosomes, extracellular vesicles, virus-like particles)
  • Applications requiring mild elution
  • Early-stage process development and clinical-scale production

Explore AVIPure HiPer PL today and elevate your purification platform.

Request a Sample

Complete this form to request an affinity resin sample. A technical specialist will contact you shortly to arrange the resin evaluation.

This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

Related Products

Repligen OPUS pre‑packed chromatography columns shown in multiple sizes, designed for scalable downstream protein purification and bioprocessing applications.

OPUS® Large-Scale Chromatography Columns

OPUS® large-scale pre-packed columns deliver proven performance from late-stage development through GMP manufacturing. By eliminating in-house packing and supporting seamless scale-up from process development, OPUS columns help reduce risk, accelerate manufacturing timelines, and improve facility efficiency for modern biopharmaceutical processes.

Read More
scientist installing RoboColumns into Tecan fluid handling station

OPUS® RoboColumn® Pre-packed Columns

LEADER OF THE PACK

OPUS® RoboColumn® miniaturized pre-packed columns are designed for automated chromatography process development and sample preparation using robotic liquid handling workstations.

Read More

OPUS® MiniChrom® Pre-packed Columns

LEADER OF THE PACK

Designed for bench-scale resin screening, process development, and sample preparation, OPUS® MiniChrom® Columns are pre-packed with user-specified resin and supplied ready to use with any liquid chromatography system. Flexible column dimension configurations (internal diameters, bed heights, volumes) allow comparative evaluation of process parameters and the construction of customized resin libraries.

Read More
KRM 10 Chromatography System with OPUS pre-packed column

KRM® Chromatography Systems

KRM Chromatography Systems are an automated single-use chromatography platform for both isocratic and gradient chromatographic batch purification processes. Designed to maximize protein purification and recovery of biomolecules, these systems reduce hold-up volume, eliminate dead legs, and enable consistent performance from process development through pilot and commercial manufacturing.

Read More